Prof. Myung-Seop Lim

Improved Loss Analysis Method Considering Core Anisotropy and AC Copper Loss in Linear Oscillating Actuator
2025-05-23 18:13:30 조회수22
Date of conference: 2025.05
Conference: The 15th International Symposium on Linear Drives for Industry Applications (LDIA 2025)
Authors: Jin-Ho Choi, Ji-Hyeon Lee, Du-Ha Park, Seong-Hyeon Kim, Soo-Hwan Park, Myung-Seop Lim
DOI:

The linear oscillating actuator (LOA) drives linear compressors with high power density and efficiency. Accurate loss calculation is crucial for  fficiency. Thus, LOA requires 3D finite element analysis due to complex structure. Conventional methods consider only direct current copper and iron  oss. This paper proposes a method incorporating core anisotropy and alternating current copper loss. Each element is introduced, and errors of  conventional and proposed methods are compared.


     