Prof. Myung-Seop Lim

2-D FEA Based Iron Loss Calculation Method for Linear Oscillating Actuator Considering Equivalent Circumferential Stack Length of Segmented Outer Stator Structure
2023-04-25 17:24:13 조회수189
Date of Conference: 2023.05
Conference: 2023 IEEE International Conference on Magnetics (INTERMAG)
Authors: Ji-Hyeon Lee, Soo-Hwan Park, Peel-Joong Kim, Du-Ha Park, Myung-Seop Lim
DOI:

The linear oscillating actuator (LOA) is an attractive option for the compressor due to their high power density and efficiency. Due to the segmented outer stator structure of the LOA, 3-D finite element analysis (FEA) is essential for calculating accurate electromagnetic loss, but it requires high computation cost. Thus, in this paper, we propose a method to reduce the computation cost calculating the iron loss using only 2-D axisymmetric FEA. To reflect the magnetic flux density increased according to outer stator structure of the LOA, the 2-D axisymmetric FEA magnetic flux density was corrected by applying an equivalent coefficient for the ratio of circumferential direction volume between full and segmented outer stator core. By using the proposed method, efficiency of the LOA can be accurately calculated without any 3-D FEA, thus the LOA can be designed efficiently. 

     
    사이트맵 닫기